Table of Contents
Wastewater Flow Calc
City of North Las Vegas
Dry Utilities
- MEP Contractor (Mechanical, Electrical, Plumbing) will coordinate with NV Energy on burying overhead power lines
- Rich Rial, rich@stfinclv.com, 702-376-0527, Start To Finish Inc.
NLV - Dry Utility
- If an existing distribution level utility pole is impacted by a proposed development, the pole will not be allowed to be replaced and the entire run of the wire for the frontage of the project must be placed underground.
Utility Plan Saw Cut
- Show pavement saw cut line on utility plan
- Construction Note
- “SAWCUT, TRENCH, BACKFILL AND ASPHALT CONCRETE RESTORATION PER CCAUSD 500.3, 500.5 & 303 AND DCSWCS 2.3.11, SD-17, SD-20, SD-21 REPAVE WIDTH MIN 8 FT WIDE.”
- Layer - CI-SAWC
- polyline, Linetype REC_STYLE 2
- hatch, ANSI31 scale 30 (or whatever the viewport scale is)
Utility Plan Signature Blocks
Clark County Fire Department
- “A Fire Prevention completed signature block on all utility sheets to be reviewed by Fire Prevention shall be provided as follows:”
- Approval of these plans shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the state or county laws. Fire Flow = _ g.p.m. at 20 psi residual.
CCWRD
- Signature block to add to all utility sheets
Sewer Notes
- DCSWCS = Design and Construction Standards for Wastewater Collection Systems - Southern Nevada 2019, 4th Edition
- Sewer Lateral Marker
Boulder City
LVVWD
Southwest Gas
New Gas Service
- email: snv-n-energysol-inq@swgas.com, 877-860-6020