ADA Design Requirements
- Min walk widths: 5'
- every 200' need a 5'x5' passing space if sidewalk width is < 5'
- Max running slopes: 12H:1V or 8.33%
- Max cross slopes: 2% but recommend designing to 1.5% - 1.8% to give the contractor some wiggle room
- Max slopes in curb ramps
- Max slopes in ADA parking and crosswalks
- Landings required at
- walks when changing directions: can't exceed 2% in any direction
- top of ramps
- front doors/building access
- Max ramp length before landing required:
- Handrails at ramps and landings
- References