Study Companion - 2012 International Residential Code
Study Session 7 (IRC Chapters 6 and 7)
- 1. What is the maximum center-to-center stud spacing permitted for a 2-inch by 6-inch, 8-foot-high wood stud bearing wall supporting two floors, roof and ceiling? (2012 IRC Study Companion, p. 185)
- a. 8 inches
- b. 12 inches
- c. 16 inches (see 2012 IRC - TABLE R602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDS)
- d. 24 inches
- 7. A bored hole shall be located a minimum of __ from the edge of a wood stud. (2012 IRC Study Companion, p. 186)
- a. 3/8 inch
- b. 1/2 inch
- c. 5/8 inch R602.6, #2 and figure R602.6(1)
- d. 1 inch
- 7jj. What is the largest size hole allowed in a single 2×4 (nominal/rough size is 2“x4” but actual/finished size is 1.5“x3.5”)
- a. 2 inches
- b. 3 inches
- c. 2.1 inches (approx. 2-1/8) (see 2012 IRC - R602.6.2 Drilling and notching of studs)
- d. 2-1/2 inches
- Solution - Check 1: 60% x 3.5“ = 2.1”
- Solution - Check 2: 3.5“ - (5/8” + 5/8“ is the closest a hole can be to either edge of the stud) = 3-1/2” - 1-1/4“ = <b>2-1/4”</b>
Roof-Ceiling Construction
- How do I install wood sheathing on top of my wooden trusses?
- “R803.2.3 Installation. Wood structural panel used as roof sheathing shall be installed with joints staggered…” (IRC 2012 for one and two-family dwellings, p. 403)